Most machinery damage happens from vibration over hundreds of miles, not from a dramatic drop. Bracing, skid design and moisture control are where crating is won or lost.

· RePallet Sale, RePallet Sale · 8 min read

Got a question this raises?

Send your question or requirement with the form, and a partner supplier follows up.

Specimen tag — request13 fields · 8 required

A partner supplier replies here

US or Canada

US state or Canadian province

US ZIP or Canadian postal code

Whole units

Free, no-obligation quote request. * required · shared with partner suppliers to prepare your quote, never sold.

The failure is usually vibration, not impact

When a crated machine arrives damaged, the instinct is to assume somebody dropped it. Occasionally true. Far more often the damage accumulated across long road miles and weeks at sea, as a part that was not fully restrained moved a few millimetres, again and again.

Vibration finds every void. A machine blocked tightly in five directions and loose in the sixth will migrate in that one direction until it contacts something it should not. Fasteners back out, shafts fret, mounting feet shear. None of it looks like impact damage because it is not.

So the first principle of machinery crating is restraint in all six directions, with no reliance on friction and no voids filled by foam alone — foam compresses, takes a set, and then stops working.

How a crate gets designed

  1. Establish weight and centre of gravity

    Not the catalogue weight — the actual shipping weight with fluids drained and loose parts separated. The centre of gravity determines skid placement, sling points and whether the crate will tip when a forklift picks it up at the far end.

  2. Identify the load-bearing structure of the machine

    Crating transfers handling forces around the product, into the frame members that can take them — never through a sheet-metal cover or a control panel. If the machine has designated lifting or mounting points, those are where the bracing connects.

  3. Design the skid base for the receiving forklift

    The forklift at the destination may be smaller, have shorter tines or a lower free-lift than yours. Skid height, spacing and the number of runners all follow from the worst-case handling equipment in the lane, not the best case.

  4. Block in six directions

    Cleats, blocks and cradles contacting the machine frame, fastened to the crate structure. Bolt-through to the skid base for heavy items. The machine should not move at all when the crate is rocked by hand.

  5. Add moisture control

    VCI film or paper on machined surfaces, desiccant sized to voyage length and cargo mass, a vapour barrier where appropriate, and a humidity indicator card so any claim can be diagnosed rather than argued.

  6. Sheath, treat and mark

    Plywood or solid board sheathing, corner cleats and a top frame for stacking. The whole assembly — frame, skids, internal bracing — is heat treated and IPPC marked on two opposite sides.

  7. Stencil what the far end needs to know

    Centre of gravity, sling points, this-way-up, do-not-stack, gross weight, dimensions. Riggers at the destination do not have your drawings and will not call to ask.

The details that decide outcomes

DetailWhy it mattersCommon failure
Skid count and spacingDistributes concentrated weight; prevents base flexingTwo skids under a heavy centre load; the base bows and the machine racks
Internal bracing fastened to structureTransfers handling loads around the productBlocks resting against the machine with nothing holding them
Foam used as a primary restraintTakes a set and stops restrainingVoid appears in week two of the voyage
Corner cleats and top frameCrates fail at corners first under stackingSheathing-only corners that crush
Desiccant sizingAbsorbs the water that leaves wood and cardboardTwo bags in a 40′ container, as decoration
Centre-of-gravity markingPrevents tipping during handling at destinationUnmarked crate tipped off a forklift
ISPM-15 on bracing and skidsPlywood is exempt; the frame is notCompliant sheathing on a non-compliant frame

Questions we get asked

Does a plywood crate need ISPM-15 treatment?

The plywood sheathing is exempt, but the cleats, corner posts, skids and internal bracing are solid wood and fully in scope. In practice this means essentially every cleated plywood crate still requires treatment and marking, because its structure is solid lumber. It is a common export compliance mistake.

How much desiccant does a crate need?

It scales with voyage length, enclosed volume and the moisture available in the cargo and packaging. Any single number quoted for all crates is a guess. Size it per shipment and include a humidity indicator card so the assumption can be checked after arrival.

Can a crate be built to a customer drawing or specification?

Often, where the requirements are documented. Mention the drawing or specification in the Message field of the quote form, and the partner supplier can tell you plainly whether it can be met before anyone commits.