Size guide
Pallet Grades: A, B, #1 and #2
There is no governing body that defines pallet grades, so a letter alone is a wish rather than a specification. Grade A generally means all deckboards present with at most one matched replacement, no plugs or companion stringers, and square to about ½". Grade B generally permits up to three replaced boards, plugs and companion stringers, mixed species and cosmetic staining. The only definition that protects you is the one written into your purchase order.
Request a quote
Quantity, grade and ZIP are enough for a partner supplier to follow up with a quote.

The uncomfortable truth about grade language
There is no certification, no audit and no standard to cite for recycled pallet grades. Two yards twenty miles apart can use the same letter to mean materially different products, and neither of them is lying.
"#1" and "Grade A" are generally used interchangeably, as are "#2" and "Grade B", but even that convention is not universal. Some yards use Grade C to mean a lower cosmetic grade of serviceable pallet; others use it to mean core, structurally broken units sold unrepaired.
The practical consequence is that the only grade definition that protects you is the one written into your own purchase order. Below is how the terms are commonly used. Use it, adapt it, or write your own, but have one.
Common grade definitions
| Grade | Condition | Repairs permitted | Typical use |
|---|---|---|---|
| Premium / A+ | Near-new appearance, consistent colour, no visible repairs | None | Brand-sensitive shipments, display, store floor |
| Grade A (#1) | All deckboards present, no plugs, minimal staining, square within ½" | Zero or one replaced board, matched lumber | Retail-facing freight, food DCs, racked storage, outbound to inspecting customers |
| Grade B (#2) | All boards present, plugs and companion stringers permitted, mixed species, cosmetic staining | Up to three replaced deckboards | Internal transfer, one-way shipments, staging, construction supply |
| Grade C / core | Structurally broken, missing boards, split stringers | Sold unrepaired | In-house repair shops; dismantled for lumber and mulch |
| Mixed / economy | Unsorted odd sizes within a dimensional band | As-is | Scrap bins, dunnage, floor protection, one-trip loads |
Condition-by-condition detail
| Condition | Grade A | Grade B |
|---|---|---|
| All deckboards present | Required | Required |
| Replaced deckboards | Maximum 1 | Maximum 3 |
| Plugged stringer | Not permitted | Permitted |
| Companion stringer | Not permitted | Permitted |
| Mixed hardwood / softwood in one unit | Not permitted | Permitted if thickness matches |
| Cosmetic staining, ink, old labels | Minimal | Permitted |
| Squareness | Within ½" | Within ¾" |
| Protruding fasteners | Zero tolerance | Zero tolerance |
| Mould bloom | Reject | Reject |
| Unknown dark or chemical staining | Reject | Reject |
| MB stamp | Reject | Reject |
| Cracked stringer in fork-entry zone | Not permitted | Not permitted |
Plugs and companion stringers, explained
These two repairs cause more purchase-order arguments than anything else, usually because buyers have never seen one properly described.
A plug is a short block of lumber fitted into a damaged area of a stringer — typically a notch that has broken out — and fastened in. Done properly it restores the bearing surface and the pallet performs normally.
A companion stringer is a full-length board nailed alongside a cracked stringer so that the pair together carry what the original carried alone. It is a genuinely sound repair; the pallet becomes slightly heavier and slightly wider at that stringer, and bending capacity is restored.
A reasonable view: for internal transfer, staging, one-way shipments and construction supply, companions and plugs are fine and the money saved is real. For racked storage, automation and anything customer-facing, buy Grade A and stop thinking about it. Many buyers specify "no companions" by instinct and then pay a Grade A premium for no functional benefit.
Writing a specification that holds
Name the footprint and design
"48x40 GMA stringer, partial four-way notched, 7 top / 5 bottom" leaves nothing to interpretation. "48x40" leaves everything.
State maximum replaced boards
A number. Three is normal for Grade B. Without a number this is the first thing that drifts when a supplier gets busy.
State whether plugs and companions are acceptable
One sentence. It is the main structural difference between the grades.
State the squareness tolerance
Half an inch or three quarters. This is the condition that causes rack and conveyor problems and it is almost never specified.
State the support condition for racking
Supported or unsupported. This single line prevents the most expensive category of mistake.
List the absolute prohibitions
Protruding fasteners, mould, MB stamps, unknown staining. Short list, zero tolerance.
Specify stack and count
Fifteen high, banded or wrapped, counted on the ground. Quantity disputes are dreary and entirely preventable.
A grade specification you can paste into a purchase order
Copy this, delete what does not apply, and attach it. It is deliberately written to survive a change of supplier.
| Line | Grade A specification | Grade B specification |
|---|---|---|
| Footprint and design | 48" × 40" GMA stringer, partial four-way notched | Same |
| Deck configuration | 7 top / 5 bottom, all present | Same |
| Maximum replaced deckboards | 1, matched thickness and species class | 3, matched thickness |
| Plugged stringers | Not permitted | Permitted, sound and fastened |
| Companion stringers | Not permitted | Permitted, full length |
| Mixed species within one unit | Not permitted | Permitted if nominal thickness matches |
| Squareness (diagonal comparison) | To ½" | To ¾" |
| Cosmetic staining, ink, labels | Minimal | Permitted |
| Protruding fasteners | Zero tolerance | Zero tolerance |
| Mould bloom | Reject | Reject |
| Unknown dark or chemical staining | Reject | Reject |
| MB-stamped units | Reject | Reject |
| Cracked stringer in fork-entry zone or notch | Reject | Reject |
| Racking support condition | State: supported on stringers / unsupported | State it |
| Maximum moisture content | State if cold chain or export: ≤19% | State if relevant |
| Deck gap maximum | State if product is small-footprint | State it |
| Stacking and count | 15 high, counted on the ground | Same |
| Off-grade remedy | Agree in advance with the supplier | Same |
Grade terminology across the trade
Terms you will encounter from other suppliers, and what they usually — not always — mean. None of them is regulated.
| Term you will hear | Usually means | What to ask |
|---|---|---|
| #1 / A grade / Premium A | Grade A: no plugs or companions, at most one replaced board | Maximum replaced boards? Plugs permitted? |
| #2 / B grade | Grade B: repairs permitted, cosmetic variation accepted | How many replaced boards? Companions allowed? |
| A+ / Premium / Display grade | Near-new appearance, no visible repairs | Is appearance specified in writing? |
| Combo / combination pallet | Mixed-species or mixed-source deck — usually Grade B territory | Does thickness match across the deck? |
| Economy / #3 / C grade | Either a low cosmetic grade or unrepaired core, depending on the yard | Is this serviceable or is it repair feedstock? |
| Core / scrap | Unrepaired, no grade promise | Confirm there is no implied serviceability |
| Export grade | Nothing standardised; usually implies HT and marked | Ask for "heat treated to ISPM-15, freshly marked, two opposite sides" |
| Heavy duty | Nothing standardised | Ask for board thickness, stringer section and a rated load |
| Rackable | Nothing without a support condition | Supported or unsupported? At what span? |
| Food grade | Nothing standardised for wood | Ask what the actual requirement is — it may need plastic |
Running an incoming inspection that takes four minutes
For buyers who want to verify rather than trust. Any receiving team can run this routine on a delivered load.
Check units from the middle of the stack, not the top
Three units from three different stacks. The top unit on a stack is the one everybody looks at, which is exactly why it tells you least.
Run a hand over the top deck
Protruding fasteners first, because that is the failure that damages product, tears wrap and cuts hands. Zero tolerance at any grade.
Count the boards and eyeball the gaps
Against your written deck configuration. A missing board is a straight reject; a gap wider than your stated maximum is too.
Flip it and look at the stringers
Full length, with attention to the notch corners and the area under the lead boards. A crack out of a notch corner is structural.
Push a corner diagonally
If the frame flexes visibly, the joints have loosened. Then check squareness by comparing the two diagonals against your tolerance.
Check the bottom deck coverage
This is what decides whether the unit can be racked unsupported. A good top deck over a mauled bottom deck is a floor pallet.
Smell it
Sounds odd, takes a second, and catches mould and chemical contamination that a visual check misses entirely.
Grade and the five applications where it is non-negotiable
- Unsupported racking
- Not a grade question at all, strictly — it is a design question. Grade A plus solid stringers plus full bottom coverage, or a block pallet with a perimeter base. A Grade A notched stringer pallet is not the answer.
- Automation and AS/RS
- Needs consistency rather than strength: a written squareness tolerance, a single board-thickness class and no repairs. Standard Grade A is not tight enough; it has to be sorted to the tolerance.
- Cold storage
- Grade A plus a stated maximum moisture content. The grade removes repair variability where retrieval from a dense freezer rack is expensive; the moisture spec prevents frost adhesion.
- Export
- Grade A, heat treated, freshly marked. Any repair with untreated lumber invalidates the mark, which is why grade and compliance are linked here and nowhere else.
- Retail floor and display
- Premium or purpose-built. The one application where cosmetic grade is a genuine functional requirement, because shoppers see the platform.
Questions we get asked
Is Grade A worth the premium over Grade B?
For racked storage, automation, cold storage and anything a customer will see, yes — it removes a category of variability for a modest cost. For internal transfer, staging and one-way domestic shipments, Grade B does the same job and the saving is real. Split your volume by application rather than buying one grade for everything.
What is the difference between #1 and Grade A?
Generally nothing — they are used interchangeably across the trade, as are #2 and Grade B. But because no body defines either term, you cannot rely on that equivalence across suppliers. Specify conditions, not letters.
Can I buy unsorted cores?
Often, if you have your own repair capability. Cores are usually the least expensive wood a recycler sells and come with no grade promise at all, so get that stated plainly on the paperwork. Availability depends on partner suppliers.
What happens if a load does not match the grade?
That depends on the partner supplier, who sets terms, so agree the remedy before you order. A written grade specification is what makes the conversation short. Inspect on arrival and raise it while the load is still identifiable.
Is there any official pallet grading standard?
No. There is no governing body, no certification scheme and no published standard for recycled pallet grades in North America — which is why two yards twenty miles apart can use the same letter for materially different products without either of them lying. The specification in your own purchase order is the only thing that protects you.
Should I specify "no companion stringers"?
Only if you have a reason. A properly fitted companion stringer restores bending capacity, so for internal transfer, staging and one-way freight it is a sound repair and the saving is real. Specify against it for racked storage, automation and customer-facing shipments. Plenty of buyers exclude them by instinct and pay a Grade A premium for no functional benefit.
Can we check a supplier's grading?
Ask the partner supplier. Whatever it can arrange, the check that always works is at your own dock: pull units out of the middle of stacks, flip them over and compare them against your written specification.
What should I do if a load is borderline?
Photograph three representative units including the undersides, note which specified condition they fail, and raise it with the partner supplier promptly while the load is still identifiable. Borderline loads are a conversation, and it is better to have it early.
Do grades mean the same thing for block pallets?
The vocabulary carries over but the conditions differ, because the failure modes differ. For block pallets the equivalent questions are block condition and replacement count, bottom runner or perimeter integrity, and stringer-board soundness. Write those conditions separately rather than assuming a stringer-pallet grade list applies.
Keep reading
Last reviewed: 2026-10-31.
Next step
Need help choosing a specification?
Send the load rather than the pallet: weight, dimensions, how it is handled and how it is stored. A partner supplier follows up on what fits.