Where a box gets its strength
A corrugated case in a stack is not a box carrying a load across its top. It is four vertical columns — the corners — with paper panels spanning between them. Compression testing consistently shows the corners carrying the large majority of the vertical load, which is why the single worst thing you can do to a case is remove support from under a corner.
Overhang does exactly that. A case whose corner projects past the pallet edge has nothing underneath it. The load from the cases above passes down into a corner that is cantilevered into thin air, the corner buckles, and the column fails. Packaging research consistently finds that even modest overhang takes a significant share of compression strength, and larger overhangs take more.
This is why a good supplier asks about product dimensions as much as pallet grade. A Grade A pallet under an overhanging load can produce more damage than a Grade B pallet under a matched load.
The cost of a mismatch
| Condition | Effect on case stacking strength | Typical consequence |
|---|---|---|
| Flush — case edge aligned with pallet edge | Full rated strength | Design behaviour |
| Modest overhang | Meaningful loss | Bottom-tier crush on tall unit loads |
| Significant overhang (2"+) | Severe loss | Visible leaning, collapsed bottom tiers, rejected deliveries |
| Underhang — product smaller than pallet | No strength loss | Wasted cube, unstable wrap, exposed pallet edge that catches |
| Diagonal overhang on one corner only | Worst case | Load racks over and the stack twists in transit |
Underhang is a cost problem, not a damage problem. Overhang is both.
Fixes, in order of how well they work
- Match the footprint to the product
- The real answer. If your case pattern wants a 44x44 platform, buy a 44x44 platform. A custom pallet stops the damage at source rather than mitigating it.
- Re-engineer the case pattern
- Sometimes the product fits the pallet in a different arrangement — pinwheel instead of column, or a different case orientation. This is free and gets overlooked constantly.
- Change the case size
- If you control your own packaging, a 1" change in case dimension can bring the pattern flush. Harder than it sounds in practice, extremely effective when achievable.
- Use a top cap and corner boards
- Does not fix the cantilever, but spreads the load above and protects the corners that remain. Worth doing regardless.
- Add a slip sheet or tier sheet at the base
- Spreads the bottom tier load slightly beyond the deckboards. A partial mitigation, not a solution.
- Increase case board grade
- Pays for the pallet mismatch forever in higher packaging cost. It works, and it is the most expensive way to work.
Deckboard gaps matter too
Related failure, same mechanism. A standard 48x40 GMA pallet has gaps between deckboards that can approach three and a half inches. A case corner landing over a gap has no support under it, exactly like an overhanging corner, and small-footprint cases on a standard deck can end up with most corners unsupported.
The fix is a closed or tighter-spaced deck — more boards, narrower gaps — or a tier sheet. If you ship small cases, bags or bundled product, specify deck spacing explicitly. It is the difference between a platform and a trap.
Questions we get asked
Is a little overhang really that bad?
Yes, and it is one of the better-documented effects in packaging engineering. The reason it surprises people is that the damage appears at the bottom of the unit load, several tiers below where the overhang is visible, so the cause and the symptom are physically separated.
What if I cannot change the pallet or the case?
Then you are managing a known weakness: reduce stack height, add top caps and corner boards, use a tier sheet at the base, and accept a higher damage allowance. Document it so nobody spends a year investigating a problem whose cause is already understood.
Does overhang affect racking too?
It affects the rack interface rather than the pallet strength. Product overhanging into the flue space of a rack bay is a fire code issue in many jurisdictions, and product overhanging the beam face is a dislodgement risk. Both are worth checking separately from the compression question.